
Tottenham / Dormer
Full Rear Zinc Dormer - Tottenham / London
This distinctive loft conversion on a Victorian property combines contemporary design with warm, natural finishes.
View case study ↗
Concept Lofts / London
Thoughtful loft design for London homes. From terraces with rear additions to hipped family semis, we plan the usable space, staircase and build around your property.
Photograph: Concept Lofts project in Tottenham · View case study
A considered first step / London
London lofts often need more than an extra room drawn into the roof. A staircase that protects the first-floor layout, enough usable headroom, the right planning route and a workable construction plan all matter. We serve the North and East London areas listed below, bringing our design and build team together from the first consultation.
01 / Built work
Published projects in Chingford, Wanstead, Upminster and Finchley show different ways to work with a rear addition, a hipped roof or an existing family layout.

Tottenham / Dormer
This distinctive loft conversion on a Victorian property combines contemporary design with warm, natural finishes.
View case study ↗
Chingford / L-Shaped Dormer
A bespoke loft conversion for this beautiful Edwardian home, designed and built by Concept from initial ideas through to completion.
View case study ↗
South Woodford / Hip to Gable
This project was completed in 2026, creating a spacious new master bedroom with a cleverly designed dressing area and a beautifully finished en-suite.
View case study ↗
Wanstead / L-Shaped Dormer
Completed in 2026, this beautiful L-shaped dormer transformed a Victorian property, adding two spacious bedrooms and a stylish shower room.
View case study ↗
Wanstead / L-Shaped Dormer
Completed in 2024, this beautiful L-shaped dormer transformed a Victorian home, with the client choosing a generous bedroom and private en-suite in the main dormer, while using the rear…
View case study ↗
Upminster / Hip to Gable + Rear Dormer
Completed in 2026, this project shows the difference thoughtful design can make.
View case study ↗
Upminster / Hip to Gable
This hip to gable conversion added a master bedroom, big ensuite and wardrobe space towards the front which we think makes best use of the space Rather than close this space off completely…
View case study ↗
Upminster / Hip to Gable
This hip to gable conversion in Upminster added a master bedroom, walk in wardrobe space with dressing area and a beautifully finished ensuite to this wonderful family home, also had a full…
View case study ↗A project in detail / Chingford

Concept designed and built this Edwardian loft conversion from the initial ideas through to completion. Recessed electric blinds span the room, while a generous walk-through shower, accessible from both ends, gives the bathroom a distinctive layout.
Outside, a rendered dormer complements the house. To achieve the clean finish the clients wanted without visible fascias, Concept designed a concealed box gutter integrated with a single-ply roofing system.
A small external detail can be central to the finished design, so it needs to be resolved as part of the construction.
Explore the Chingford project ↗A real completed project / Chingford
02 / Roof and property
An L-shaped dormer needs a suitable rear addition; an older terrace alone is not enough. A hipped semi may suit a hip-to-gable and rear dormer after assessment. Flats and maisonettes need separate checks of roof ownership, lease and freeholder consent as well as planning and building control. Every option below is assessment-dependent; a property type alone does not establish planning eligibility.
| Property or roof | Option worth investigating | Main constraint |
|---|---|---|
| Terrace or semi with usable rear roof | Rear dormer ↗ | Available roof volume, height, appearance and stair landing |
| Semi or end terrace with a hipped side roof | Hip-to-gable ↗ | Hipped roof geometry and the new gable design |
| Hipped roof with usable rear slope | Hip-to-gable + rear dormer ↗ | Both additions share the relevant roof-volume allowance |
| House with a suitable rear addition | L-shaped dormer ↗ | Rear-addition roof, connection and combined structural design |
| Roof with enough usable space without enlargement | Rooflight / Velux ↗ | Still needs structural floor, stairs, fire and insulation design |
| Roof where a changed profile is appropriate | Mansard ↗ | Often needs a planning application and substantial roof work |
| Bungalow with conversion potential | Bungalow conversion ↗ | Ground-floor stair position, roof height and structure, fire design and planning |
Think about daylight, privacy and solar shading alongside insulation and ventilation. Eaves can make useful storage, but an en-suite needs drainage and sensible access. The new stairs should not take away the very bedroom space you are trying to gain.
Compare a main bedroom and bathroom against two smaller rooms on a measured layout. The best roof option balances headroom and useable space with the rest of the home.
Read the staircase guide ↗03 / Budget and scope
Cost depends on roof form, usable floor area, structure, staircase, bathroom and specification. An itemised, property-specific quote follows assessment. A rooflight scheme generally has a lower structural scope than a larger combined roof enlargement, but even rooflight projects need a new floor, compliant stairs and fire design.
Read the detailed London cost guide ↗Street access, deliveries and parking can also affect the programme and quote in London.
These are items to check, not a promise that every item is included in every quote.
04 / Approvals
On houses with householder rights, Class B roof enlargement may qualify as permitted development: up to 40m³ for terraces or 50m³ for other houses, including earlier roof additions. The addition cannot rise above the existing highest roof or project beyond the principal highway-facing roof slope. Materials, windows and eaves conditions also matter. Class B does not apply on designated land such as conservation areas; rooflights have separate Class C rules. This is a summary, not a complete eligibility checklist.
Flats and maisonettes do not have householder Class B roof-extension rights. Listed buildings, conservation areas, Article 4 directions and earlier conditions require checks. A Lawful Development Certificate is useful evidence of lawfulness, not Building Regulations sign-off. Where permission is needed, local design policy applies; it does not override national permitted development rights.
London boroughs set design policies for proposals requiring planning permission, but an SPD does not override national permitted development rights. Conservation and Article 4 constraints still need address-specific checks.
Read national technical guidance ↗/Planning guide ↗Chingford, Walthamstow
The residential alterations and retrofit SPD was adopted in June 2026 for planning design; it does not replace national PD tests.
Woodford, Ilford, Wanstead
The borough's loft guidance covers structure, fire, stairs and building applications.
Upminster, Romford, Hornchurch
Check the property's borough planning context.
Crouch End, Muswell Hill
Check the address and relevant constraints.
Stratford, Forest Gate
Check the address and relevant constraints.
Other covered addresses may fall under different authorities; confirm with the council for the actual property.
Design and inspections cover structure, protected escape and fire precautions, stairs and headroom, insulation and ventilation, drainage and electrics, with completion evidence. Requirements vary for bungalows, existing storeys and flats; the whole escape route needs assessment.
Stair and fire-safety guide ↗Cutting beam bearings into a shared wall can be notifiable. Check required notices early and involve a suitable surveyor where needed. Party wall procedure is separate from planning and building control, and not every loft needs an award.
Official party wall guidance ↗05 / From first visit to handover
On-site chat about your ideas and budget, then a transparent quotation with free proposed floorplans.
A detailed measure of your home, taking around 45 minutes.
Drawings, 3D model, planning or LDC as needed and structural calcs — handled in-house by our design team.
Full plans submitted for building regulations approval.
Typically 5–6 weeks on site, with a full week-by-week schedule shared in advance.
Sign-off, cleanup and your 10 year guarantee.
Construction is typically 5–6 weeks on site. Design and consents, party wall matters, the wait for a start date and decorating can extend the overall calendar time; approvals cannot be guaranteed.
Many households stay at home. Roof access can help contain early work, but a stair opening, internal work, dust, noise, service interruptions and safe access still need a plan. See the full process ↗
Client perspective
“Would highly recommend Jake and Concept Loft Rooms Ltd. Great all the way through. In contact throughout to make sure we were happy with the progress, build was quick and to a very high standard. Extremely pleased with the end product.”
Read more reviews ↗
06 / Coverage
Explore our local guides below, or contact us to discuss your address and the space you want to create.
07 / Questions
Roof form, structure, staircase, usable floor area, bathroom and finish determine the scope. Proposed floorplans are free with the consultation and quotation; check the itemised quote for the full drawing, calculation, application and fee scope, inclusions and VAT.
A typical conversion takes around 5–6 weeks on site. Design, consents, party wall matters, waiting for a start date and decorating can extend the total calendar time.
Some houses retain roof-extension rights under Class B: up to 40m³ for terraces and 50m³ for other houses, including earlier enlargements. Other position, height, appearance and property conditions apply. Conservation areas, listed buildings and removed rights need particular checks; Building Regulations approval is separate.
Measure the roof geometry, then allow for the new floor and insulation to see how much usable headroom remains. The existing landing and escape route also guide where compliant stairs can be designed.
Possibly. The answer depends on usable space, daylight, the staircase, access and the needs of the rooms below. Proposed floorplans make those trade-offs visible.
Sometimes, with a designed replacement structure and temporary support. The roof must be surveyed; trusses cannot simply be cut out.
Often, yes. Roof-level access can limit early disturbance, but the stair opening, internal work, dust, noise and occasional service interruptions still need planning.
Not every project needs an award. Works such as cutting beam bearings into a shared wall can require notice; check early and use a suitable surveyor where needed. This is separate from planning and building control.
Possibly, but householder Class B roof-extension rights do not apply. Roof ownership, lease terms, freeholder consent, planning permission and building control must all be checked.
Only if there is a suitable rear addition and the roof and planning context allow it. Its two wings need structural and design assessment together.
Scaffolding, deliveries, parking and neighbour access may change the programme and quote. We discuss those practical constraints for the actual address.
Class B roof enlargement rights do not apply on designated land including conservation areas. A planning application and sensitive design may be required; check other consents too.
Your home / London
Tell us about your North or East London home and the room you want to gain.

Fill in the form below and a member of our team will be in touch to arrange your appointment.